Elastic Modulus considered for EN 13445-3 should be as per Design temperature

While designing heat exchanger as per EN 13445-3, AutoPIPE Vessel is considering elastic modulus at mean metal temperature but elastic modulus values should be taken at design design temperature. Refer attached snap.
Tanaji Gaikwad over 1 year ago in  1 Future consideration

Create custom flange for a nozzle

Sometimes designers want to create a custom flange specially for large diameter nozzle which can then be checked as a body flange (Appendix 2 etc.). Currently this can be done as a separate model but an option to include custom flange to a nozzle ...
Sudip Ganguly about 1 year ago in  0 Needs review

Possibilité d'incorporer des tubulure rectangle/carrée

Nous avons très régulièrement des demandes client pour calculer des appareils suivant différents codes, avec des tubulures carrées et/ou rectangulaires. Est'il possible d'intégrer ce genre de tubulures dans autopipe vessel? We regularly receive cu...
Guest 2 months ago in  3 Needs review

Calcul suivant CODAP - Partie C12

Lors de calcul de double enveloppe, nous avons constaté qu'AUTOPIPE VESSEL n'intégre pas la partie C12 du CODAP. C'est un manque important dès qu'il y a double enveloppe. Nous supposons également que si ce manque est existant au niveau du CODAP il...
Guest 3 months ago in  0 Needs review

ASME Appendix Y flange

ASME Appendix Y - Flat face flanges with metal-to-metal contact outside the bolt circle
Sudip Ganguly over 1 year ago in  0 Planned

Updating PD 5500

Please could we add the latest additions of PD 5500 to the design standards. In South Africa, the competing design codes are ASME and PD due to the selection of materials that our legislation permits. As a result, ensuring that Bentley AutoPIPE Ve...
Tristan Northing about 1 year ago in  0 Needs review

Longitudinal loads: add longitudinal wind and longitudinal bending moments

Today only transversal wind is considered, but longitudinal wind may be significant for big vessel. In addition, those moments and loads whould be found in the foundation loads. Also, if a External load is applied, the only moment availalbe ("bend...
Vivianne Genin over 1 year ago in  0 Planned

Expansion Bellows - Option to input the number of half-convolutions (e.g. 2.5)

It is not possible to set 2.5 Convolutions (N). In some cases, I have to consider bellow with 2.5 convolution, but I cannot design as there is no option to enter this value.
Tanaji Gaikwad 11 months ago in  0 Needs review

Parameters for skirt design in EN13445 (and CODAP)

Please add the possibility to enter the values lt, ht and eat according to EN13445 16.12.4 for the design of skirt. In my attached file, when changing lt to 179.7 mm and eat to 7.7 mm, the formula (16.12-70) is now verified without changing the sk...
Guest 9 months ago in  0 Needs review

Girth flange calculation - Override bolt area

Add an option to override the selected bolt area. This can be helpful when non standard neck-down bolt is used.
Guest over 1 year ago in  1 Needs review