Allow a calculation full of liquid

A tall vessel or column is normally designed with a particular liquid level. It would be very helpful if a new user case can be defined allowing to calculate full of liquid (which is not water, it is not the same as hydrotest).
Guest 3 months ago in  0 Needs review

Nozzle loads on supports

When it is added local loads for nozzles, these loads should be taken in consideration for the support calculation and fundation loads considering the location and orientation of nozzle, for example, Nozzle A located on top head has local loads su...
Guest 3 months ago in  0 Planned

Transport saddles calculation for vertical vessels

Add saddles for transport on vertical vessels. Calculation should be similar to horizontal vessel on saddles, but with transportation loads. This will eliminate need for an additional model for transport. Transport will be part of report and will ...
Guest 6 months ago in  0 Future consideration

Elastic Modulus considered for EN 13445-3 should be as per Design temperature

While designing heat exchanger as per EN 13445-3, AutoPIPE Vessel is considering elastic modulus at mean metal temperature but elastic modulus values should be taken at design design temperature. Refer attached snap.
Tanaji Gaikwad 8 months ago in  0 Future consideration

Do not display the "Equivalent beam model" paragraph in the calculation report (wind, earthquake, ... calculations)

It would be useful for users to have the option of not displaying the “Detailed characteristics of the equivalent beam model” paragraph in the calculation report when a wind/seismic analysis is performed. Indeed, in "Vessel properties", tab "Repor...
Guest 4 months ago in  0 Needs review

ASME Appendix Y flange

ASME Appendix Y - Flat face flanges with metal-to-metal contact outside the bolt circle
Sudip Ganguly 4 months ago in  0 Planned

Lifting accesoires: handled independently.

They appear in the list of components, the 2D and 3D view. Local loads for them can be checked in Design Component. Their welds appear in the weld map.
Vivianne Genin 8 months ago in  1 Future consideration

API 650 storage tank code update - 13th Edition, 2020

No description provided
Sudip Ganguly 3 months ago in  0 Needs review

Girth flange calculation - Override bolt area

Add an option to override the selected bolt area. This can be helpful when non standard neck-down bolt is used.
Guest 6 months ago in  0 Needs review

Add API620

When API650 is not suitable for a vertical tank, calculation should be done with API620
Guest 6 months ago in  0 Needs review