Jacket closure calculation according to PD 5500

We have noticed that the software systematically considers all jackets as type 2 in the jacket closure calculation following PD 5500. We need you to integrate the concept of type 1 jackets in the next version to facilitate support for this type of...
Guest 6 months ago in  1 Needs review

Allow a calculation full of liquid

A tall vessel or column is normally designed with a particular liquid level. It would be very helpful if a new user case can be defined allowing to calculate full of liquid (which is not water, it is not the same as hydrotest).
Guest 3 months ago in  0 Needs review

Do not display the "Equivalent beam model" paragraph in the calculation report (wind, earthquake, ... calculations)

It would be useful for users to have the option of not displaying the “Detailed characteristics of the equivalent beam model” paragraph in the calculation report when a wind/seismic analysis is performed. Indeed, in "Vessel properties", tab "Repor...
Guest 4 months ago in  0 Needs review

API 650 storage tank code update - 13th Edition, 2020

No description provided
Sudip Ganguly 3 months ago in  0 Needs review

Girth flange calculation - Override bolt area

Add an option to override the selected bolt area. This can be helpful when non standard neck-down bolt is used.
Guest 6 months ago in  0 Needs review

Add API620

When API650 is not suitable for a vertical tank, calculation should be done with API620
Guest 6 months ago in  0 Needs review

Add Greek seismic code EAK 2000 and its 2003 ammedments

Greece is a country with high seismic behaviour. Many industrial projects are on going in Greece, it would be beneficial to add Greek seismic code.
Guest 7 months ago in  0 Needs review

Codap - Opening with pad according to C5.1.4b13

Nozzles design: Please provide an opction that considers the alternative calculation method when there is an insert forged pad
Guest 8 months ago in  0 Needs review

EN1092-1 - Leave the user the choice between table and calculation

The allowable pressure of flanges as per EN1092-1 can be defined by formulas or by table. In the past AutoPipeVessel was giving the table allowable pressure. In the new version, it's the calculation with the allowable stress of the material. It wo...
Guest 8 months ago in  0 Needs review

API 579 Fitness for Service (FFS)

Implement FFS as per API 579. Parts of API 579 include: 1 – Introduction 2 – FFS Engineering Evaluation Procedure 3 – Brittle Fracture 4 – General Metal Loss 5 – Localized Metal Loss 6 – Pitting Corrosion 7 – Blisters, HIC, and SOHIC Damage ...